Material
Somos® BioClear
Description
Somos® BioClear can produce clear and accurate anatomical models, surgical guides, and functional prototypes that can be used for body contact. The material has passed ISO 10993-5 Cytotoxicity, ISO 10993-10 Irritation and Sensitization, and USP Class VI testing. It is an excellent material for small-batch runs and customizable parts for the dental, medical, and scientific industries. Parts created using this material are optically clear and have similar mechanical properties to ABS.
Key Characteristics
Clear/Translucent
High Strength • High Resolution/High Detail
Chemical Resistant • Moisture Resistant
Biocompatible – Please notify us of any biocompatibility needs.
Applications
- Surgical Models
- Surgical Guides
- Medical Applications
- Functional Prototypes
Mechanical Properties
Tensile Strength
7,300 psi
Elongation at Break
15.5%
Flexural Strength
10,000 psi
Flexural Modulus
320 ksi
Heat Deflection at 264 psi
120° F
Resources
Technology
Stereolithography
Max Build Area
31 x 31 x 23 in
Lead Time
1 – 2 Days
Tolerances
First inch ± .005 in
Additional inches ± .0015 in
Layer Thickness
Normal resolution .004 in
Minimum feature .012 in.
High-resolution .002 in
Minimum feature .006 in
Are you ready to get a quote?
Stereolithography Design Considerations
Feature
Measurement
Supported Walls
.02 in
Unsupported Walls
.04 in
Supports & Overhangs
Base Support Otherwise 45 Degrees
Embossing & Engraving
Width: .016 in, Height/Depth: .016 in
Horizontal Spans
.08 in
Holes & Openings
.02 in
Connecting & Moving Parts
.03 in
Escape Holes
.04 in
Minimum Features
.008 in
Pin Diameter
.03 in